3.6 Hiding the Alarm Indication
Select whether to enable the alarm hide function.
For a description of the function, see section 1.2.
Setup Screen
Press MENU (to switch to setting mode), hold down FUNC for 3 s (to switch to basic
setting mode), and select the Environment tab > Alarm > Action.
Setup Items
Alarm action > No logging
To enable the function that turns off the alarm indicator and logging, select On. The
Detect setup item is displayed in the alarm setting screen (see section 3.7).
This function disables the alarm indicator and the logging of alarm events to the alarm
summary. Alarms are also not displayed by the alarm annunciator (release number 3
or later).
Settings for Each Channel and Each Alarm
See section 3.7.