4. Operation Procedure
The parameters are converted in two steps as described below.
Step 1
UploadtheparametersoftheoriginaldevicetoFieldMateandsavetheminale.
App.C01E.ai
Upload Save
Original device FieldMate
Figure App.-C-1
Step 2
Retrievetheparametersfromtheleanddownloadthemtothereplacingdevice.
App.C02E.ai
Retrieve
Download
FieldMate Replacing device
Figure App.-C-2
• AttheendofStep1,theparametersareautomaticallysavedinale(cannotbecanceled).
• Steps1and2canbeconsecutivelyperformed.Or,afterStep1isnished,Step2canbe
done later.
(Note) This tool works only for the combinations of devices listed in Table D-1.