Zobrazit stránku 0
IM 12B6J8-01E-E
1st edition
Instruction
Manual
Model FU24F
pH/ORP SENCOM™ sensor
Zobrazit stránku 0
1 2 3 4 5 6 ... 19 20

Shrnutí obsahu

Strany 1 - Instruction

IM 12B6J8-01E-E 1st editionInstructionManualModel FU24FpH/ORP SENCOM™ sensor

Strany 2

IM 12B6J8-01E-E 10CSA Certificate no. : 2516979 Master contract no. : 182892 IS, Class I Div. 1, GP A, B, C, D T3…T6 Electrical data : For se

Strany 3

IM 12B6J8-01E-E 11FM Certificate no. : 3046277 IS, Class I Div. 1, GP A, B, C, D T3…T6 Electrical data : For sensor input circuits (by connecto

Strany 4

IM 12B6J8-01E-E 12Note: When the sensor has been connected to not intrinsically safe equipment which exceeds the restrictions regarding the sensor in

Strany 5 - 1. PREFACE

IM 12B6J8-01E-E 134. DIMENSIONSFig 4: Dimensions FU24F sensor257.5 ±1.7 (10.14” ±0.07)192 ±1.1 (7.56” ±0.04”)70 ±0.9 (7.56” ±0.04”)243.5 ±1.7 (9.59: ±

Strany 6

IM 12B6J8-01E-E 145. WIRINGThe FU24F is provided with a multipole M9 male connector for connection to the Yokogawa FLXA analyzer using the WU11 interc

Strany 7 - 2. GENERAL SPECIFICATIONS

IM 12B6J8-01E-E 156.2 Calibration for ORP and rH measurementFor calibration of ORP and rH, the procedure for MANUAL CALIBRATION can be used as describ

Strany 8

IM 12B6J8-01E-E 167. MODEL CODEModel Code Suffix Code Option DescriptionFU24F SENCOM™ pH Wide Body SensorModel - NPT Dome shape model - FS

Strany 9

IM 12B6J8-01E-E 179. EU DECLARATION OF CONFORMITY 1/2 YOKOGAWAEU DECLARATION OF CONFORMITY We: Yokogawa Europe B.V. Euroweg 2 3825 HD Amersfoor

Strany 10

IM 12B6J8-01E-E 18Model Code Suffix Code Option Code DescriptionFU24F SENCOM™ pH Wide body SensorModel - NPT Dome shape model - FSM Flat

Strany 11

IM 12B6J8-01E-E 1910. CHEMICAL COMPATIBILITY CHART Material PVDF S.S. 316 VITON PEEK PP PVC PFA (Kynar)Sulfiric acid 10 OOO XXX

Strany 12 - 3. INSTALLATION OF FU24F

IM 12B6J8-01E-E 2(BG)Всички улътвания за продукти от серията ATEX Ex ce лредлагат на английски език. Ако се нуждаете oт улътвания за продукти oт серия

Strany 13 - 4. DIMENSIONS

IM 12B6J8-01E-E Printed in The Netherlands, 01-1402Subject to change without notice Copyright ©IM 12X0X0-E-ESubject to change without notice Printe

Strany 14 - 5. WIRING

IM 12B6J8-01E-E 3(LV)Visas ATEX Ex kategorijas izstrâdâjumu Lietoðanas instrukcijas tiek piegâdâtas angïu valodâs. Ja vçlaties saòemt Ex ierîèu dokume

Strany 15

IM 12B6J8-01E-E 4CONTENTS1. PREFACE 51.1 Introduction 51.2 Unpacking and Checking 51.3 Warranty and Service 61.4 Serial Number definition 62. GEN

Strany 16 - 8. SPARE PARTS

IM 12B6J8-01E-E 51. PREFACE1.1 IntroductionThis Instruction Manual provides information for the installation and use of the FU24F SENCOM™ sensor. This

Strany 17 - YOKOGAWA

IM 12B6J8-01E-E 61.3 Warranty and ServiceYokogawa products are guaranteed free from defects in workmanship and materials under normal use and service

Strany 18

IM 12B6J8-01E-E 72. GENERAL SPECIFICATIONS 2.1 Measuring elementspH glass electrodeAg/AgCl referenceSolid Platinum electrodePt1000 temperature sensor2

Strany 19 - IM 12B6J8-01E-E

IM 12B6J8-01E-E 82.5 Operating rangepH : 0 to 14 ORP : -1500 to 1500 mV rH : 0 to 100 Temperature - Dome shape : -10 °C to 105 °C (14 °F to

Strany 20 - Copyright ©

IM 12B6J8-01E-E 92.8 Regulatory standardsCE : Decision 768/2008/EC - ATEX : Directive 94/9/EC, as amended by Regulation (EC) no. 1882/2003