2-5
IM WX1-06E
Operating Procedure
Note
You can set multiple monitor intervals in the same system. If the same monitor interval is set for
the MW100, it is assigned to each system in order from smallest measurement group number.
Also, if the number of same monitor intervals is greater than the actual number of measurement
groups, only the actual number of measurement groups is valid.
2.
To display channel information, click the Channel tab.
You can also choose Channel from the View menu.
Click
Click the number to highlight the channel information
of the corresponding unit
Highest two digit: Registered unit number
Lowest three digit: Channel number (000 to 099), Math channel (more than 100)
Note
• The channel information is displayed only for channels that are set to acquire data in the
MX100/MW100 settings.
• If the number of channels set in step 2 exceeds the actual number of channels that exists
in the MX100/MW100, the portion of nonexistent channels is left blank. If the number of
channels is less than the actual number of MX100/MW10 channels, only the set channels
are displayed.
• If the connection fails, the channel information for the corresponding MX100/MW100
appears as a blank line.
• If the channels of the modules installed to the MX100/MW100 do not match the channels
displayed in the Channel tab, perform reconfiguration using the MX100 Standard Software
or the Browser.
• The System No. from the channel information display is shown when information is retrieved
or when setting the System column in the System Configuration screen.
• Click System No. to sort the channel information by system number. Click System No.
again to sort the channel information by channel number.
Click here to sort the
channel information
by system number
2.3
Retrieving Information about the Target MX100s/MW100s and Setting the Number of Channels and the Monitor Interval