UsingtheEthernetInterface
2.5 Accessing Measured Data Files on the MV from a
PC
You can access data files stored on an external storage medium.
ConguringtheFTPServer
Press MENU and then select Menu tab > Basicsettingmode > Menu tab >
Communication (Ethernet)> Server
• FTP
Set the FTP parameter under Server to Use or Not (don’t use).
AccessingtheMVfromaPC
You can use the following functions when the FTP server is enabled.
AccessingaDataFilefromaWebPage
If the Data File to Be Retrieved Is Already Generated
1.
Click the Data list link.
2.
Click Memory or Media.
3.
Select the file you want to retrieve from the file list.
4.
Drag and drop the file to the desired folder on the PC.
Note
The Internal memory link is ftp://hostname/MEM0/DATA.
The External media link is ftp://hostname/DRV0/.