MW100
CAN Bus Module Configuration Tool
(MX118-CAN-M30/S1)
Users Manual
All Rights Reserved. Copyright © by Yokogawa Electric Corporation IM MX118-S1E-2 Ed-02
Zobrazit stránku 0
1 2 3 4 5 6 ... 39 40

Shrnutí obsahu

Strany 1

1 MW100 CAN Bus Module Configuration Tool (MX118-CAN-M30/S1) User’s Manual All Rights Reserved. Copyright © by Yokogawa Electric Corpora

Strany 2

10 2. Using the Configuration Tool 2.1. Connecting the MX118 Perform the following procedure to connect the MX118 to the PC and place it in Setti

Strany 3 - 1. Before Using the Software

11 2.2. Serial Communication Settings Enter serial communication settings to configure the MX118. 1. Choose Communication > Settings. Or, c

Strany 4

12 2.3. CAN Communication Settings (General Screen) Enter the slot width and CAN communication related settings. If the General screen is not dis

Strany 5

13 CAN Bit Rate (bps) You can set the speed of CAN bus communication. Select a bit rate from the following values. If you select Other, the detaile

Strany 6

14 Baud Rate Prescaler (BRP) You can set the baud rate prescaler value. The available setting range is 1-256. Time Quanta Count (TQC) You can set

Strany 7

15 2.4. Setting the Message ID (Message Screen) You can enter settings related to the CAN message ID. If the Message screen is not displayed, cli

Strany 8

16 2.5. Channel Settings (Channel Screen) For each measurement channel, you can enter settings related to extracting and normalizing measured data

Strany 9

17Start Bit Pos. You can specify a start bit position for extraction of data to be measured included in the data field. Enter the lsb number of the m

Strany 10

18Value Min. / Max. You can enter the upper and lower limits of measured data. The values that can be entered vary depending on the Value Type and Bi

Strany 11

19 2.6. Copying and Pasting Settings Settings in the Message and Channel screens can be copied to other message numbers or channels. 1. Click

Strany 12 - [More] button

2 Contents 1. Before Using the Software ...

Strany 13

20 2.7. Sending and Receiving Settings Receiving Settings You can receive settings from the MX118 and load them onto the software. 1. Choose Co

Strany 14

21 2.8. Displaying Module Information You can acquire information about the MX118 module connected to the PC. 1. Choose Communication > Modu

Strany 15

22 2.9. Saving and Loading Settings Saving Settings You can save settings created on the configuration tool to a file. 1. Choose File > Save

Strany 16

23 Loading Settings Files You can load a previously saved settings file. 1. Choose File > Open. Or, click Open on the toolbar. 2. Select

Strany 17

24 2.10. Creating New Settings You can initialize the settings. Choose File > New. Or, click New on the toolbar. Note When creating new

Strany 18

25 2.11. Printing Settings You can print a list of settings, preview printing, and enter printer settings. Print 1. Choose File > Print. Or, c

Strany 19

26Print Preview Choose File > Print Preview. An image of the printout is displayed. Print Setup... Choose File > Print Setup. The Print

Strany 20 - Click here

27 2.12. Changing to Measurement Mode Disconnect the MX118 from the PC before switching to Measurement mode. 1. Turn OFF the power to the MW100

Strany 21 - Max Slot Width

28 3. Troubleshooting 3.1. Troubleshooting STATUS LED does not light (blink) (Measurement mode or Setting mode) Possible Problem Corrective Actio

Strany 22

29 Cannot take measurements (when ACTIVE LED does not blink). Possible Problem Corrective Action Refer to Page Cable not connected. Check CAN cab

Strany 23

3 1. Before Using the Software 1.1. Explanation of Functions Overview of Functions A one-to-one connection can be made between the MX118-CAN-M30 CA

Strany 24

30 3.2. Error Messages and Corrective Actions Message Description/Corrective Actions Refer to Page Cannot connect to the target module. Turn ON th

Strany 25 - Message Settings

31 4. Appendix 4.1. Bit timing table Detailed set selecting items possible range in each Bit rate. The abbreviation in the table shows the followin

Strany 26

32 Bit Rate = 20K Bit Timing BRP TQC SS TSEG1 TSEG2 SJW BSP 24 25 1 16 8 1,2,3,4 1 15 8 1,2,3,4 1 25 24 1 16 7 1,2,3,4 1 11 8 1,2,3,4 1 12 7

Strany 27

33 Bit Rate = 33.3K Bit Timing BRP TQC SS TSEG1 TSEG2 SJW BSP 15 8 1,2,3,4 1 15 24 1 16 7 1,2,3,4 1 11 8 1,2,3,4 1 12 7 1,2,3,4 1 13 6 1,2,3,4 1

Strany 28 - 3. Troubleshooting

34 Bit Rate = 50K Bit Timing BRP TQC SS TSEG1 TSEG2 SJW BSP 15 8 1,2,3,4 1 10 24 1 16 7 1,2,3,4 1 11 8 1,2,3,4 1 12 7 1,2,3,4 1 13 6 1,2,3,4 1 1

Strany 29

35 Bit Rate = 83.3K Bit Timing BRP TQC SS TSEG1 TSEG2 SJW BSP 15 8 1,2,3,4 1 6 24 1 16 7 1,2,3,4 1 9 8 1,2,3,4 1 10 7 1,2,3,4 1 11 6 1,2,3,4 1 1

Strany 30

36 Bit Rate = 100K Bit Timing BRP TQC SS TSEG1 TSEG2 SJW BSP 15 8 1,2,3,4 1 5 24 1 16 7 1,2,3,4 1 11 8 1,2,3,4 1 12 7 1,2,3,4 1 13 6 1,2,3,4 1 1

Strany 31 - 4. Appendix

37 Bit Rate = 250K Bit Timing BRP TQC SS TSEG1 TSEG2 SJW BSP 15 8 1,2,3,4 1,3 2 24 1 16 7 1,2,3,4 1,3 8 7 1,2,3,4 1,3 9 6 1,2,3,4 1,3 10 5 1,2,3

Strany 32 - Bit Rate = 20K

384.2. Default of bit timing The default of a detailed setting of each bit rate is shown in the following. Bit Timing Bit Rate [bps] BRP TQC SS T

Strany 33 - Bit Rate = 33.3K

39 4.3. Example of Extracting Measured Data This shows how to count bit numbers in the MX118. With Big Endian, from the start of the data field,

Strany 34

4 1.2.1. Operation Guide Set up MW100, Install MX118Connect serial cable Connect power cable Start configuration toolSet slot width Set bit rate Se

Strany 35 - Bit Rate = 83.3K

40 Data Field Length = 8 Bytes For Big Endian: Available start bit position settings: 0–(Bit Length-1) For Little Endian: Available start bit positi

Strany 36

5 1.3.PC System Requirements PC A PC with an Intel Pentium III, 800-MHz CPU or higher and at least 256 MB of memory. OS (Operating System) Windows

Strany 37

6 1.4. Setting Up the Software The following procedures apply to software installation on Windows XP. 1. Turn ON the power to the PC and start W

Strany 38

7 6. Enter the installation directory then click Next. The default directory is C:MX118 CAN Bus. Change the directory if necessary. 7. Click

Strany 39

8 Installation Results If the software is properly installed, a folder named MX118 CAN Bus is created in the specified directory (on the C: drive by

Strany 40

9 1.5. Launching and Exiting the Software Launching the Software As shown in the figure below, choose Start > Programs > MX118 CAN Bus > M