Yokogawa Button Operated MV2000 Uživatelský manuál Strana 187

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 310
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 186
6-33
IM MV1000-01E
Display Configuration
1
2
3
4
5
6
7
8
9
10
11
12
13
App
Index
6.16 Writing a Message When the MV Recovers
from a Power Failure
This section explains how to configure the MV to write a message to the trend display
when the MV recovers from a power failure that occurs during memory sampling.
Display
Power Recovery Message
MV1000
Press MENU and then select Menu tab > Basic setting mode > Environment tab >
View, Message.
MV2000
Press MENU and then select Menu tab > Basic setting mode > Environment tab >
View, Message, Input, Alarm.
Settings
Message > Power-fail message
Setting Description
On Automatically writes a message when the MV recovers from a power failure that
occurs during memory sampling.
Display example: 15:12 Power Off 2008/01/23 15:12:57
Off Disables this function.