Yokogawa Data Acquisition with PID Control CX2000 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Senzory Yokogawa Data Acquisition with PID Control CX2000. Yokogawa Data Acquisition with PID Control CX2000 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 59
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Operation
Guide
Yokogawa Electric Corporation
IM 04L31A01-02E
6th Edition
Model CX2000/CX2010/CX2020/CX2200/CX2210/CX2200/
CX2410/CX2420/CX2610/CX2620
DAQSTATION CX2000
Zobrazit stránku 0
1 2 3 4 5 6 ... 58 59

Shrnutí obsahu

Strany 1 - DAQSTATION CX2000

OperationGuideYokogawa Electric CorporationIM 04L31A01-02E6th EditionModel CX2000/CX2010/CX2020/CX2200/CX2210/CX2200/CX2410/CX2420/CX2610/CX2620DAQSTA

Strany 2 - Contents

10 IM 04L31A01-02EList of Control Setup ItemsBasic Control Setup Items in Basic Setting Mode#1 Control action, Input settingPID number, control period

Strany 3 - Revisions

11IM 04L31A01-02EExamples of Control Setup OperationControl Setup Example 1: Single Loop ControlObject of Control and DescriptionSSRCX2000Electricfurn

Strany 4 - PID Control Function

12 IM 04L31A01-02E2.Press the #1 soft key (Control action, Input setting).3.Press the arrow keys to move the cursor (blue) to the setup item box, pres

Strany 5 - Control Suppression Function

13IM 04L31A01-02ESetting the Control Input Range in Setting Mode1.From the operation display, click the MENU key to display the control setting menush

Strany 6 - Control Alarm Function

14 IM 04L31A01-02ESetting Control Alarms in Setting Mode1.From the operation display, click the MENU key to display the control setting menu.2.Press t

Strany 7 - CX2000 Installation

15IM 04L31A01-02EControl Setup Example 2: Cascade ControlObject of Control and DescriptionCX2000High limit temperature alarmLow limit temperature alar

Strany 8 - Overview of Operations

16 IM 04L31A01-02ESelect 1(No need to set loop 2)Select CascadeSelect Tem orPress+Flow4.Press the ESC key to return to the basic control setting menu.

Strany 9 - Control Operation Display

17IM 04L31A01-02E9.Press the End soft key.A confirmation window shown below opens.10.Press the DISP/ENTER key to confirm the settings.Setting the Cont

Strany 10 - List of Control Setup Items

18 IM 04L31A01-02E6.Set the input range of the secondary loop of cascade control in a similar fashion asdescribed in steps 3 to 5 and according to the

Strany 11 - Menu (Basic setting mode 2/2)

19IM 04L31A01-02ESetting Alarms on the Secondary Loop of Cascade ControlSelect 1Set to 0.90Select DO003Select OnSelect PV-HighSelect OnSelect 2Setting

Strany 12 - IM 04L31A01-02E

2 IM 04L31A01-02EContentsIntroduction to Control Functions ...

Strany 13

20 IM 04L31A01-02ESetting PID Parameters on the Secondary Loop of Cascade ControlSelect 2Select ReverseSelect 1Set to P=120.0% I=20 s,D=0 s(No need to

Strany 14

21IM 04L31A01-02E2.Press the #1 soft key (Control action, Input setting).3.Press the arrow keys to move the cursor (blue) to the setup item box, press

Strany 15

22 IM 04L31A01-02E3.Press the arrow keys to move the cursor (blue) to the Input type box, press the PV1soft key, and set other parameters as shown in

Strany 16

23IM 04L31A01-02ESetting PID Parameters in Setting Mode1.From the operation display, click the MENU key to display the control setting menu.2.Press th

Strany 17

24 IM 04L31A01-02E2.Press the #1 soft key (Control action, Input setting).3.Press the arrow keys to move the cursor (blue) to the setup item box, pres

Strany 18 - Set to 0.00

25IM 04L31A01-02E2.Press the #1 soft key (Control input range).3.Press the arrow keys to move the cursor (blue) to the setup item box, press the softk

Strany 19

26 IM 04L31A01-02ESetting the Display Items on the Control Group Display (Control Group Setting)Below are the procedures for displaying loops 1 to 5 a

Strany 20

27IM 04L31A01-02EDisplaying the Trend of PV, SP, and OUT ValuesBelow are the procedures for displaying the trends of PV, SP, and OUT of loop 1 on thet

Strany 21 - Cycle time

28 IM 04L31A01-02ENoteYou can select up to 10 channels from measurement channels (CH1 to CH20), computationchannels (CH31 to CH60), internal control c

Strany 22

29IM 04L31A01-02ESwitching the Operation ModeFor details on the procedure for switching the operation mode, see chapter 6,“Operations during Control O

Strany 23

3IM 04L31A01-02EThank you for purchasing the CX2000. This operation guide briefly explains the mainoperations related to the loop control function of

Strany 24

30 IM 04L31A01-02EChanging the Target Setpoint1.Use the arrow keys to move the cursor to the desired control loop.2.Press the SP soft key.The SP modif

Strany 25

31IM 04L31A01-02ESwitching between Remote and Local ModesThe soft key menu does not show REM/LOC, if Control > Contact input-registration/AUX(Alarm

Strany 26

32 IM 04L31A01-02EChanging the Analog Retransmission OutputMAN must be set for the MODE using the procedure above.1.Use the arrow keys to move the cur

Strany 27 - Channel input

33IM 04L31A01-02ETuning OperationFor details on the procedure of switching the operation mode, see chapter 6, “Operationsduring Control Operation” in

Strany 28 - 28 IM 04L31A01-02E

34 IM 04L31A01-02EManual Tuning1.Press the arrow keys on the tuning display.A cursor appears in the control parameter display section.2.Select the con

Strany 29 - MODE selection window

35IM 04L31A01-02EProgram Control Function (/PG1 and /PG2 Options)Program Control Function IntroductionProgram control function is used to ramp-up or r

Strany 30 - Changing the Control Output

36 IM 04L31A01-02EProgram Selection Display ExampleProgram pattern nameSelected patternnumberSelected segment*numberSelected segment*timeSegment range

Strany 31 - Window for switching between

37IM 04L31A01-02EResetting Program ControlResets the program control and stops.1.Press the RUN/RST soft key.A pop-up window for starting and resetting

Strany 32 - Auto/manual switching window

38 IM 04L31A01-02EExecuting Several Program PatternsYou can execute multiple program patterns whose loop numbers do not overlap.Switching Pattern Numb

Strany 33 - Tuning Operation

39IM 04L31A01-02EProgram Control Related Setup OperationsFollow the flow chart below.For further details on each function, see section 1.11, “Program

Strany 34 - Manual Tuning

4 IM 04L31A01-02EIntroduction to Control FunctionsFor further details on each function, see chapter 1, “Explanation of Functions” in theCX2000 User’s

Strany 35 - /PG2: 30 patterns

40 IM 04L31A01-02EPattern Initial SettingEnter the program pattern number./PG1: 1 to 4, /PG2: 1 to 30Select the time or ramp-rate (see below).Enter th

Strany 36 - Window for executing/

41IM 04L31A01-02EPattern Start SettingEnter the SP of the pattern start point.Select the operation when starting the program control (see below).Selec

Strany 37

42 IM 04L31A01-02EProgram Pattern Setting• When the segment setting method is set to [Time]Select the segment number.Select the wait zone number to be

Strany 38

43IM 04L31A01-02E• When the event kind is set to [PVEvent]Select the segment number to which the event is to be assigned.Select [PVEvent] (see below).

Strany 39

44 IM 04L31A01-02EList of ParametersBelow is a list of parameters for the model with the various function options. However,settings related to the pro

Strany 40

45IM 04L31A01-02E#4 Key loginParameter Selectable Range or Selections Initial ValueKey login > Use/Not Use/Not NotKey login > Auto logout On/Off

Strany 41 - Pattern Start Setting

46 IM 04L31A01-02E#7 Communication<#1 Ethernet, Serial>Parameter Selectable Range or Selections Initial ValueEthernet > IP-address – 0.0.0.0E

Strany 42

47IM 04L31A01-02E<#5 AUX>Parameter Selectable Range or Selections Initial ValueRecovery Status for Comm. Buffer > DO/SW Continue, Clear Clear

Strany 43

48 IM 04L31A01-02E<#6 Report E-Mail Settings>Parameter Selectable Range or Selections Initial ValueReport E-Mail settings > Recipient1 On/Off

Strany 44 - List of Parameters

49IM 04L31A01-02EParameter Selectable Range or Selections Initial ValueAUX > Loop number 1 to 6 1AUX > Remote setting Off or Remote OffAUX >

Strany 45 - #6 Option

5IM 04L31A01-02EPID Parameter Selection MethodYou can select the method for switching PID parameters from the following:• Target setpoint selection: B

Strany 46 - <#4 Modbus master>

50 IM 04L31A01-02EParameter Value or Selections Initial ValueControl mode SingleLoopControl, CascadePrimaryLoop, CascadeSecondaryLoop, SingleLoopContr

Strany 47

51IM 04L31A01-02EParameter Value or Selections Initial Value#3 Tuning settingTuning setting > Loop number Ext1 to Ext16 Ext1Tuning setting > 01

Strany 48 - #10 Control

52 IM 04L31A01-02E#3 Operation-related parameter/zone PIDParameter Selectable Range or Selections Initial ValueOperation related/zone PID > Loop nu

Strany 49 - <#5 Tuning setting>

53IM 04L31A01-02E#7 Program control related (only when program control is ON)<#1 Program parameter setting>Parameter Selectable Range or Selecti

Strany 50 - 50 IM 04L31A01-02E

54 IM 04L31A01-02E<#3 AUX (Auto message, Display position)>Parameter Selectable Range or Selections Initial ValueAUX (Auto message, Display posi

Strany 51 - #2 Control alarm

55IM 04L31A01-02E<#4 DI/DO label setting>Parameter Selectable Range or Selections Initial ValueDI/DO label setting > Module CTRL1-DI, CTRL2-D

Strany 52 - #6 Ten-segment linearizer I/O

56 IM 04L31A01-02ESet mode#1 Range, AlarmParameter Selectable Range or Selections Initial ValueFirst-CH 01 to 20 01Last-CH 01 to 20 01Range > Mode

Strany 53

57IM 04L31A01-02E<#2 Color>Parameter Selectable Range or Selections Initial ValueColor > CH1, CH11 Red, green, blue, blue violet, brown, oran

Strany 54 - 54 IM 04L31A01-02E

58 IM 04L31A01-02EList of Parameters<#6 Control (Zone, Graph (, Partial))>Parameter Selectable Range or Selections Initial ValueFirst-CH 101 to

Strany 55 - <#3 Constant>

59IM 04L31A01-02EList of Parameters#6 TimeParameter Selectable Range or Selections Initial ValueTime set > YY/MM/DD HH/MM/SS – –#7 Math set1 (expre

Strany 56 - 56 IM 04L31A01-02E

6 IM 04L31A01-02EPreset OutputThis function sets the control output to the preset value when the operation is stopped.SP Ramp-Down-Rate/SP Ramp-Up-Rat

Strany 57 - <#5 Control (Color)>

7IM 04L31A01-02EWiringInput/Output terminals are arranged on the rear panel of the CX2000 as shown in thefigure below. The figure shows the case when

Strany 58 - #5 Save/Load, Clear data

8 IM 04L31A01-02EOverview of OperationsKey OperationFor details on the key operation, see chapter 3, “Names of Parts, Display Modes, andCommon Operati

Strany 59 - #9 Batch set

9IM 04L31A01-02EControl Operation DisplayIn operation mode, the following control operation displays can be selected.• Control group displayThis displ

Komentáře k této Příručce

Žádné komentáře