7-16 IM 04L31A01-17E
mmm...m Message (up to 20 characters)
The communication log contains only the error number and not the
error message section.
Normally, the transfer data are transmitted as they are, but in some
cases, a special message is output. The special messages are
shown below.
Reception
(Over length): Command length exceeded.
(Over number): Number of commands exceeded
(Serial error): Received an error character through serial
commuk Cations.
Transmission
(ddd byte): data output (ddd is the number of data points)
(Login): login
(Logout): logout
(Disconnected): Forced disconnection (occurs when the connection
was disconnected when transmitting data using
Ethernet)
(Time out) : Timeout, keepalive, TCP retransmission, etc.)
E1 nnn: Single negative response where nnn is the error
number.
E2 ee:nnn: Multiple negative response where ee is the error
position and nnn is the error number.
_ Space
Example
The following example shows the log when multiple commands separated by sub
delimiters, “B01;???;CS1,” are transmitted. The commands are separated and
output in order with the multiple command flags “*.
EA
99/05/11 12:31:11 1 user *> BO1
99/05/11 12:31:11 1 user *< E0
99/05/11 12:31:11 1 user *> ???
99/05/11 12:31:11 1 user *< E2 01:124
99/05/11 12:31:11 1 user *> CS1
99/05/11 12:31:11 1 user *< E0
EN
7.2 Output Format of ASCII Data