IM 01E20D01-01E
6-13
6. OUTLINE
English Units (Size: in., Flow rate: GPM)
0 to Min. Span Flow Rate
(0.33ft/s)
0 to Max. Span Flow Rate
(33ft/s)
0to0.0078 GPM0.1 0 to 0.7780 GPM
0to0.03120.2 0 to 3.112
0to0.12450.4 0 to 12.44
0to0.19460.5 0 to 19.45
0to0.77811.0 0 to 77.80
0to1.2161.25 0 to 121.5
0to1.751
1.5
0to175.0
0to3.1132.0 0 to 311.2
0to4.8632.5 0 to 486.2
0to7.0033.0 0 to 700.2
0to12.454.0 0 to 1,244
0to19.465.0 0 to 1,945
0to28.016.0 0 to 2,800
0to49.808.0 0 to 4,979
0to77.8110 0 to 7,780
0to112.112 0 to 11,203
0to152.514 0 to 15,249
0to199.216 0 to 19,918
Size
(in.)
0to311.320 0 to 31,122
0to448.224 0 to 44,815
0to610.028 0 to 60,999
0to796.832 0 to 79,672
0to1,00936 0 to 100,835
0to1,24540 0 to 124,488
T24.EPS
0 to Min. Span Flow Rate
(1.0ft/s)
0 to Max. Span Flow Rate
(33ft/s)
0to4,519 GPM44 0 to 150,630 GPM
0to5,37848 0 to 179,262
0to6,80754 0 to 226,879
0to8,40360 0 to 280,098
0to9,56164 0 to 318,689
0to12,10172 0 to 403,341
0to14,93980 0 to 497,952
0to18,07688 0 to 602,522
0to21,51296 0 to 717,051
0to25,247104 0 to 841,540
Size
(in.)
T24-1.EPS
Fluid Temperature and Pressure:
Note *1 The following figures show maximum allowable
fluid pressure for the flowtube. Further fluid
pressure should also be limitted according to
flange rating.
*2 For fluid temperature of the explosion proof type,
refer to descriptions of “HAZARDOUS AREA
CLASSIFICATION”.
PFA Lining (*1)
General-Purpose Use, Submersible Type, Explosion
proof Type, Remote Flowtube (electrode structure
code 1: Non-replaceable electrode)
Pressure
MPa (psi)
4 (580)
2 (290)
1 (145)
– 0.1 (–14.5)
– 40
(–40)
40
(104)
100
(212)
160
(320)
Temperature °C (°F)
130
(266)
2.5 to 50 mm (0.1 to 2.0 in.) (flange type, wafer type)
65 to 200 mm (2.5 to 8.0 in.) (flange type, wafer type)
250, 300 mm (10, 12 in.) (flange type)
250, 300 mm (10, 12 in.) (wafer type)
350, 400 mm (14, 16 in.) (flange type)
0
(32)
–10
(14)
F18-1.EPS
150
(302)
*1
General-Purpose Use and Explosion proof Type,
Integral Flowmeter (electrode structure code 1: Non-
replaceable electrode)
Pressure
MPa (psi)
4 (580)
2 (290)
1 (145)
0.1 (–14.5)
– 40
(– 40)
40
(104)
100
(212)
Temperature °C (°F)
130
(266)
0
(32)
–10
(14)
2.5 to 50 mm (0.1 to 2.0 in.) (flange type, wafer type)
65 to 200 mm (2.5 to 8.0 in.) (flange type, wafer type)
250, 300 mm (10, 12 in.) (flange type)
250, 300 mm (10, 12 in.) (wafer type)
350, 400 mm (14, 16 in.) (flange type)
F18-2.EPS
*1
*1: For wafer types of 32 mm to 300 mm(1.25 to 12 in.), and
for carbon steel flange types (process connection code:
C
**
) of 50 to 400 mm (2.0 to 16 in.), the minimum tem-
perature is –10°C (14°F).
*2: For fluid temperature of the explosion proof type, refer
to descriptions of “HAZARDOUS AREA CLASSIFI-
CATION”.