IM 01R04B08-00E-E 1st edition February 15, 2012 -00
All Rights Reserved. Copyright © 2012, Rota Yokogawa
<7. MODBUS REGISTERS>
7- 2
Parameter Data range
Selection
value
Unit
Read
Holding
Register
Input
Register
Write
Execute Address (decimal)
Mass ow unit
g/s 70
- R/W 1072 45
g/min 71
g/h 72
kg/s 73
kg/min 74
kg/h 75
kg/d 76
t/min 77
t/h 78
t/d 79
lb/s 80
lb/min 81
lb/h 82
lb/d 83
MassowLRV -Qmax to Qmax - Mass ow unit R/W 1088
MassowURV -Qmax to Qmax - Mass ow unit R/W 110 4
Mass ow damping 0 to 200 - Sec. R/W 112 0
Mass ow lowcut 0to10%ofQmax - Mass ow unit R/W 113 6
Mass ow alm 1 sel
Nofunction 0
- R/W 115 2More than 1
Less than 2
Mass ow alm 1 crit -110%to110%ofURV - Mass ow unit R/W 116 8
Massowxvalsel
Inhibit 0
- R/W 1216
Enable 1
Massowxedval -Qnom to Qnom - Mass ow unit R/W 1232
Komentáře k této Příručce