IM 01R04B08-00E-E 1st edition February 15, 2012 -00
All Rights Reserved. Copyright © 2012, Rota Yokogawa
<7. MODBUS REGISTERS>
7- 4
Parameter Data range
Selection
value
Unit
Read
Holding
Register
Input
Register
Write
Execute Address (decimal)
Volowalm1sel
Nofunction 0
- R/W 1328More than 1
Less than 2
Volowalm1crit -110%to110%ofURV - Volowunit R/W 1344
Density unit
g/ml 95
- R/W 1392 47
kg/l 96
kg/m³ 92
lb/gal 93
lb/Cuft 94
g/cm³ 91
g/l 97
°Béhv 102
°Bé lt 103
°API 104
DensityLRV 0 to 5 kg/l - Density unit R/W 1408
DensityURV 0 to 5 kg/l - Density unit R/W 1424
Density damping 0 to 200 - Sec. R/W 1440
Density lowcut 0 to 5 kg/l - Density unit R/W 1456
Density alm 1 sel
Nofunction 0
- R/W 1472
More than 1
Less than 2
Density alm1 crit 0 to 5 kg/l - Density unit R/W 1488
Densityxvalsel
Inhibit 0
- R/W 1536
Enable 1
Reference Density 0 to 5 kg/l - Density unit R/W 1552
Density offset -9999.99 to +9999.99 - g/l R/W 1568
Pressure 0 to 400 bar - Pressure Unit R/W 1584
Pressure unit
bar 7
- R/W 1600
psi 6
MPa 237
Temperature unit
degC 32
- R/W 1616 48degF 33
K 35
TemperatureLRV
Standard:
-200 to 230°C
0
Temperature unit R/W 1632
High Temp.:
0 to 400°C
1
TemperatureURV
Standard:
-200 to 230°C
0
Temperature unit R/W 1648
High Temp.:
0 to 400°C
1
Temperature damping 0 to 200 - Sec. R/W 1664
Temp alm 1 sel
Nofunction 0
- R/W 1680More than 1
Less than 2
Temp alm 1 crit
Standard:
-200 to 200°C
- Temperature unit R/W 1696
Tempxvalselect
Inhibit 0
- R/W 174 4
Enable 1
Tempxedval
Standard:
-200 to 230°C
0
Temperature unit R/W 1760
High Temp.:
0 to 400°C
1
Komentáře k této Příručce