IM 01R04B08-00E-E 1st edition February 15, 2012 -00
All Rights Reserved. Copyright © 2012, Rota Yokogawa
<10. GENERAL SPECIFICATIONS>
10-2
Integral Type RCCT3, Option Code :
Options Option
code
Description Restrictions
HazardousAreaApprovals /KF1
/KF2
/FF1
/FF2
/EF1
/EF2
/UF1
/UF2
ATEXFlameproofconverter+Intrinsicsafedetector
ATEXFlameproofconverter+Intrinsicsafedetector+Intrinsicsafeoutputs
FMapprovalforUSA+Canada,Flameproofconverter+Intrinsicsafedetector+2
activeanalogoutputs+2passivepulseoutputs+1statusinput
FMapprovalforUSA+Canada,Flameproofconverter+Intrinsicsafedetector+
1passiveanalogoutput+1passivepulseoutput
IECExFlameproofconverter+Intrinsicsafedetector
IECExFlameproofconverter+Intrinsicsafedetector+Intrinsicsafeoutputs
INMETROFlameproofconverter+Intrinsicsafedetector
INMETROFlameproofconverter+Intrinsicsafedetector+Intrinsicsafeoutputs
with /HP for gas group IIB
with /HP for gas group IIB
onlywithcableconduit´A´;with/HPnotfor
groupsAandB
onlywithcableconduit´A´;with/HPnotfor
groupsAandB
with /HP for gas group IIB
with /HP for gas group IIB
with /HP for gas group IIB
with /HP for gas group IIB
Custody Transfer Measurement
acc. OIML R 117-1
/Q01 EuropeanMIDApproval(uidsotherthanwater)(refertoGS01R04B07-00E)
GOST /QR1
/QR2
/QR3
PrimaryCalibrationandTestConrmationvalidinRussia
PrimaryCalibrationandTestConrmationvalidinKazakhstan
PrimaryCalibrationandTestConrmationvalidinUzbekistan
see page 9
see page 9
see page 9
DualSealApproval /DS
/RD
DualSealapproval(conformwithANSI/ISA-12.27.01)
Rupture disk
onlywith/FF1;notwithprocessconnectionA5;
notwitRCCT39/XR,preferablewith/GA,manda-
toryif/DS+/GAisselected
HighDrivingPower /HP HighDrivingPower not for RCCT34, recommended for RCCT36
to 39, strongly recommended for RCCT39/IR,
mandatory for RCCT39/XR
Communication /FB
/MB1
Digital communication Foundation Fieldbus protocol (refer to GS 01R04B05-00E)
Modbuscommunicationprotocolforselectedparametersandvalues notwith/FB,/Q01,/KF2,/EF2,/UF2,/FF2,/AP
ActivePulseOutput /AP Oneactivepulseoutput notwith/KF2,/EF2,/UF2,/NM
NAMURSwitch /NM Onepulseoutputacc.toEN60947-5-6(NAMUR) notwith/AP
TagNumber /BG With customer specied tag number on name plate max. 16 digits
HARTTagNumber(SoftwareTag) /BT1 WithcustomerspeciedtagnumberforHARTcommunicationinconverter 8 digits for tag, 22 digits for long tag
Flange Facing /DN
/RJ
Flangewithsafetygroovesacc.toEN1092-1formD
Ring Type Joint Flanges
onlyforD2toD6;notHC
onlyforA3,A4,A5;notHC
Gas Measurement /GA Gas measurement, special factory adjustments and settings tobeconformwithANSI/ISA-12.27.01select/RD
Special Calibration /K2
2)
/K4 /
K5
2)
/K6
Custom5ptsmass-/volume-owcalibrationusingwaterwithfactorycerticate
(traceable to German national standards)
Densityadjustment+thermaltreatment;(accuracy:0.001g/cm³)
Custom10ptsmass-/volume-owcalibrationusingwaterwithDKDcerticate
(accordingEN-17025:2005)
Densitycalibrationwith3differentuidsincl.individualtemperaturecompensation
with certicate (accuracy: 0.0005 g/cm³)
onlyRCCT34to39;notwith/GA
onlyRCCT34to39;notwith/GA
Certicates /P2
/P3
/P6
/P8
/H1
/WP
Certicateofcompliancewiththeorderacc.toEN10204:2004-2.1
As/P2+Testreportacc.toEN10204:2004-2.2(QIC)
Materialcerticateacc.toEN10204:2004-3.1
Pressure test report measuring system
Oilandfatfreeforwettedsurfaceacc.toASTMG93-03levelC
WPSacc.DINENISO15609-1(WeldingProcedureSpecication)
WPQRacc.DINENISO15614-1(WelderPerformanceQualicationRecord)
WQCacc.DINEN287-1(WelderQualicationCerticate)
only for butt weld between process connection
andowdivider;notformaterialHC
Sanitary Type /SF1
/SF2
/SA
/SE
SurfaceroughnessRa=0.8µm
As/SF1+Testreportroughnessofwettedparts
As/SF2+3A-declarationofconformityand3A-mark
As/SF2+EHEDGcerticate
notRCCT39/XR;onlyprocessconnectionsS2,
S4,S8;
see also restrictions in table 11
not with process connection S2
not with process connection S2
Customer Presetting /PS Presetting sheet with customer data has to be issued with the order
Housing Pressure Test /J1 Rupture pressure proof test and certicate:
60 bar (RCCT34, RCCT36), 40 bar (RCCT38), 10 bar (RCCT39, RCCT39/IR)
not for RCCT39/XR
X-Ray Examination /RT X-ray examination of ange welding RCCT34 with /K4 or /K6 only one-sided
PMI Examination /PM6 PAMItest(6testpoints:processconnectioninlet+outlet,measuringtubes,ow
dividerinlet+outlet)
3)
Dye Penetration Test /PT Dye penetration test of ange welding
Epoxy Coating /X1 Epoxycoatingofconverterhousing
Concentration Measurement
4)
/CST
/Cxx
Standard concentration measurement
Advancedconcentrationmeasurement,detailsseetable„AdvancedConcentration
Measurement Options“
DeliverytoJapan /PJ FormeterswhicharedeliveredtoJapan,withSI-unitpreset
DeliverytoKorea /KC With KC-mark for Korea
Cable glands /AD2 2 pcsANSI1/2“NPT/G1/2adapter onlywithcableconduit´A´
Instruction Manuals /IEn
/IDn
/IFn
Quantity of instruction manuals in English
Quantity of instruction manuals in German
Quantity of instruction manuals in French
n=1to3selectable
5)
n=1to3selectable
5)
n=1to3selectable
5)
QuickDelivery /QD Deliverywithin24hoursfromfactory not RCCT39/IR, RCCT39/XR,
notwithprocessconnectionsize23,12,
onlywithprocessconnectionratingA1,A2,D4,
only material SL,
onlyforoptions/KF1,/FF1,/EF1,/UF1,/HP,/AP,
/NM,/NA,/BG,/P2,/P3,/P8,/CST,/Cxx,/IEn,/
IDN,/IFn
Special order /Z Special design must be specication an extra sheet
2)
Calibrationordersheetmustbedeliveredwiththeorder.ThisisavailableontheFlowCenterPageatCoriolis/RCCx3/TechnicalInformation.
3)
MeasuringtubePAMItestisperformedperdeliverybatch.
4)
For detailed information please see TI 01R04B04-04E-E. Concentration measurement is recommended with option /K6.
5)
Ifnoinstructionmanualisselected,onlyaDVDwithinstructionmanualsisshippedwiththeinstrument.Morethan3manualsofonelanguageonrequest.
Komentáře k této Příručce