IM 01E30D01-01EN
4
IM 01E30D01-01EN
<INSTALLATION AND OPERATING PRECAUTIONS FOR TIIS FLAMEPROOF EQUIPMENT>
Do not attempt to re-process threaded
connectionsorrenishjointsormatingsurfaces.
(c) Unlessotherwisespecied,theelectrical
circuitry and internal mechanisms may be
repaired by component replacement, as this
will not directly affect the requirements for
ameproofapparatus(however,bearinmind
that the apparatus must always be restored to
its original condition). If you attempt to repair
theameproofapparatus,company-specied
components shall be used.
(d) Before starting to service the apparatus, be sure
to check all parts necessary for retaining the
requirementsforameproofapparatus.Forthis,
check that all screws, bolts, nuts, and threaded
connections have properly been tightened.
(3) Prohibitionofspecicationchangesand
modications
D
onotattempttochangespecicationsormake
modicationsinvolvingadditionoforchangesin
external wiring connections.
7. Selection of Cable Entry
Devices for Flameproof Type
The cable glands (cable entry devices for
ameprooftype)conformingtoIECStandards
arecertiedincombinationwiththeameproof
apparatus.So,Yokogawa-speciedcableentry
devicesforameprooftypeshallbeusedtomeet
this demand.
References:
(
1) TypeCerticateGuideforExplosion-Protected
Construction Electrical Machinery and
Equipment (relating to Technical Standards
Conforming to International Standards), issued
by the Technical Institution of Industrial Safety,
Japan
(
2) USER’S GUIDELINES for Electrical
Installations for Explosive Gas Atmospheres
in General Industry (1994), issued by the
Japanese Ministry of Labour, the Research
Institute of Industrial Safet