<4. WIRING>
4-7
IM 01E30D01-01EN
F0415.ai
SUPPLY
DO
Power supply
cable
Figure 4.6.2 Electric Cable Wiring (TIIS Explosion
Proof Type)
• ConnectingwiththecommercialAXR
powersupplywilldamagetheowmeter.
Be sure to use the DC power supply in the
predetermined range.
• Do not connect power supply with reversed
polarities.
SUPPLY + terminal: connect +
SUPPLY - terminal: connect -
Supply voltage means the voltage necessary
to provide between the power terminals of the
magneticowmeter.
Refer to Table 4.6.2 to 4.6.4 for wiring examples in
case of general - purpose use/explosion proof type
except TIIS.
Refer to Table 4.6.5 to 4.6.7 for wiring examples in
case of TIIS explosion proof type.
T
heADMAGAXRcanbeconnectedwithalmost
all distributors, signal conditioner cards, and I/O
modules except certain devices.
Referring to the Table 4.6.1 for Yokogawa’s devices,
choose an appropriate connecting device and the
corresponding length of cable.
For devices other than Table 4.6.1, decide on
the connection by referring to the supply voltage
specicationsandthedescriptionofwiring
examples as shown in Table 4.6.2 to 4.6.7.
Table 4.6.1 Connecting device and Applicable
maximum cable length (guideline)
Connecting device
Maximum length of cable
(rough guideline)
Name Model
Cable
with cross
section of
2 mm
2
Cable
with cross
section of
1.25 mm
2
Signal
Conditioner
Card
EA1
EA2
2 km 2 km
I/O Module
AAM11
AAM11B
2 km 2 km
Analog I/O
Module
(for FIO)
AAI143 2 km 2 km
AAI141
AAI841
AAI135
AAI835
Not applicable Not applicable
Analog I/O
Module (for
Prosafe-RS)
SAI143 1.4 km 0.8 km
Distributor
SDBT
SDBS
2 km 2 km
JUXTA
VJA1
2 km 2 kmVJA4
VJA7
Communication Requirement:
BRAIN
Communication signal:
BRAIN communication signal
(superimposed on 4 to 20 mA DC signals)
Conditions of Communication Line:
Supply Voltage: 20.6 to 42 V DC
LoadResistance:250to600Ω
(including cable resistance)
Refer to Figure 4.6.3.
Communication Distance:
Up to a distance of 2km when a CEV cable is
used (Refer to Table 4.6.2)
LoadCapacitance:0.22μForless
Load Inductance: 3.3 mH or less
Distance from other Power line:
15 cm (6 in.) or more (Avoid parallel wiring)
Input Impedance of Communicating Device:
10kΩormoreat2.4kHz